Residential · Repair

12301 WYCLIFF LN

Emporia Pro NACS Emporia Vue Energy Monitor Proposed installation plan: Install a new 60A circuit in the 125A main service panel and route wiring through a surface-mounted conduit along the exterior wall to the left exterior side wall of the garage. Hardwire the Emporia Pro NACS and configure to draw up to 48A continuous. Additional installation notes: The Emporia Vue energy monitor is included with the Emporia Pro charger and must be installed inside the main service panel to monitor whole-home energy usage. Install CT clamps and activate device in ap

Permit number2026-141050 EP
DescriptionEmporia Pro NACS Emporia Vue Energy Monitor Proposed installation plan: Install a new 60A circuit in the 125A main service panel and route wiring through a surface-mounted conduit along the exterior wall to the left exterior side wall of the garage. Hardwire the Emporia Pro NACS and configure to draw up to 48A continuous. Additional installation notes: The Emporia Vue energy monitor is included with the Emporia Pro charger and must be installed inside the main service panel to monitor whole-home energy usage. Install CT clamps and activate device in ap
Class / work typeResidential · Repair
Valuation—
StatusActive
AppliedOctober 26, 2026
IssuedOctober 29, 2026
Council district7
Address / ZIP12301 WYCLIFF LN, Austin, TX 78727
City of Austin sourceView official record →